|
Temperature/Climatic Stress Screening Chambers, Series TS and CS
Our temperature and climatic stress screening test cabinets are designed using a modular concept from the standard series. The powerful compressor and high fan capacity
allow extremely high temperature variation rates up to 30 K / min with conventional refrigeration technology and up to 70 K / min. with liquid nitrogen. These units will give you the possibility to determine the stress
limits of your specimen very quickly.

Standard version of the product line "TS/CS": |
 |
multicolor touch panel / 32 Bit Controller |
 |
service-friendly capacitive humidity measurement system |
 |
single-hand operated door handle, lockable |
 |
entry port ø 50 mm |
 |
shelf, stainless steel |
 |
display in plain text |
 |
potential free contact for malfunction signal |
 |
RS 232 interface |

Your benefits: |
 |
service-friendly construction |
 |
minimum noise level |
 |
extremely high temperature change rates |
 |
simple user-friendly operation and programming |
 |
low power-consumption datas |
 |
optimized parameters for highest testing precision |
 |
complies with current CE and EMC regulation |
 |
demineralised water system with water-level gauge |
Test space capacity in liters:
|
 |
5 K/min 200 / 350 / 600 / 1000 / 1500 |
 |
10 K/min and 15 K/min 200 / 350 / 500 / 810 / 900 / 1250 |
Temperature range:
|
 |
-40 °C / +180 °C
-70 °C / +180 °C |
Temperature change rates:
|
 |
5 to 30 K/min |
Design:
|
| Control: |
microprocessor control and monitoring system |
| Test space: |
stainless steel grade 1.4301 |
| Refrigerants: |
chloride free, hermetically sealed |
Humidity system (only type CS): |
capacitive measuring |
Options:
|
 |
add. entry ports ø 50 mm, 80 mm und 125 mm |
 |
add. shelves |
 |
panoramic window, multiple glazed, sized 570 x 710 mm |
 |
hand-hole in the door |
 |
add. Pt 100 for temperature measuring on test specimen alternative reversible to controller function |
 |
air dryer system |
 |
mobile design |
 |
temperature protection for test-specimen |
 |
water cooled compressor; external condenser |
 |
CID software for programming and documentation |
 |
variable air speed in the test space |
 |
RS 232 interface changeable to USB |
 |
ETHERNET interface RJ 45 |
| Type |
5 K/min |
| |
TS -40/..., CS -40/... TS -70/..., CS -70/... |
-40/200-5 -70/200-5 |
-40/350-5 -70/350-5 |
-40/600-5 -70/600-5 |
-40/1000-5 -70/1000-5 |
-40/1500-5 -70/1500-5 |
| Test Space |
liters |
200 |
350 |
600 |
1000 |
1500 |
| Test Space Dimensions |
|
height |
mm, appr. |
750 |
750 |
850 |
900 |
900 |
| |
width |
mm, appr. |
650 |
650 |
850 |
1000 |
1000 |
| |
depth |
mm, appr. |
400 |
720 |
830 |
1100 |
1600 |
| Overall Dimensions |
|
height |
mm, appr. |
1800 |
1800 |
1900 |
1950 |
1950 |
| |
width |
mm, appr. |
920 |
920 |
1120 |
1270 |
1270 |
| |
depth |
mm, appr. |
1345 |
1665 |
1875 |
2245 |
2745 |
| |
| Temperature Tests |
| Temperature Range |
TS -40/..., CS -40/... |
°C |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
| TS -70/..., CS -70/... |
°C |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
Temp. Change Rate Cooling |
TS -40/..., CS -40/... |
K/min |
5,0 |
5,0 |
7,0 |
5,0 |
5,0 |
| acc. IEC 60068-3-5 |
TS -70/..., CS -70/... |
K/min |
5,0 |
5,0 |
7,0 |
5,0 |
5,0 |
Temp. Change Rate Heating |
TS -40/..., CS -40/... |
K/min |
8,0 |
8,0 |
6,0 |
6,0 |
5,0 |
| acc. IEC 60068-3-5 |
TS -70/..., CS -70/... |
K/min |
8,0 |
8,0 |
6,0 |
6,0 |
5,0 |
max. Thermal Load at +20°C |
TS -40/..., CS -40/... |
W |
3500 |
3500 |
4500 |
5000 |
6000 |
| TS -70/..., CS -70/... |
W |
3500 |
3500 |
5000 |
5500 |
5000 |
| Temperature Fluctuation |
K |
≤± 0,3 temporally |
| |
| Climatic Tests |
| Temperature Range |
CS -40/..., CS -70/... |
°C |
+10 to +95 |
| Humidity Range |
CS -40/..., CS -70/... |
% RH |
10 to 98 |
| Dew Point Range I |
CS -40/..., CS -70/... |
°C |
+7 to +94 |
| Dew Point Range II |
CS -40/..., CS -70/... |
°C |
-10 to +7 |
| Humidity Fluctuation I |
CS -40/..., CS -70/... |
% RH |
≤± 1,5 |
| Humidity Fluctuation II |
CS -40/..., CS -70/... |
% RH |
≤± 3 |
| Temperature Fluctuation |
CS -40/..., CS -70/... |
K |
≤± 0,3 |
| Nominal Voltage |
400 V +6% -10%, 3/N, 50 Hz |
| Nominal Power |
TS -40/... |
kW, appr. |
9,3 |
9,3 |
9,2 |
13,3 |
13,2 |
| CS -40/... |
kW, appr. |
10,4 |
10,4 |
12,1 |
13,2 |
13,2 |
| TS -70/... |
kW, appr. |
10,9 |
10,9 |
14,2 |
16,4 |
16,4 |
| CS -70/... |
kW, appr. |
12,0 |
12,0 |
14,2 |
16,4 |
16,4 |
| Condenser |
|
air-cooled |
water-cooled |
| Weight |
TS -40/..., CS -40/... |
kg, appr. |
500 |
600 |
700 |
850 |
1000 |
| TS -40/..., CS -40/... |
kg, appr. |
550 |
650 |
750 |
900 |
1100 |
| Noise level |
|
dB(A) |
< 58 |
< 58 |
< 62 |
< 62 |
< 62 |
| Type |
10 K/min |
| |
TS -40/..., CS -40/... TS -70/..., CS -70/... |
-40/200-10 -70/200-10 |
-40/350-10 -70/350-10 |
-40/500-10 -70/500-10 |
-40/900-10 -70/900-10 |
-40/1250-10 -70/1250-10 |
| Test Space |
liters |
200 |
350 |
500 |
900 |
1250 |
| Test Space Dimensions |
|
height |
mm, appr. |
750 |
750 |
820 |
870 |
870 |
| |
width |
mm, appr. |
650 |
650 |
850 |
1000 |
1000 |
| |
depth |
mm, appr. |
400 |
720 |
725 |
1000 |
1400 |
| Overall Dimensions |
|
height |
mm, appr. |
1800 |
1800 |
2170 |
2230 |
2230 |
| |
width |
mm, appr. |
920 |
920 |
1120 |
1270 |
1270 |
| |
depth |
mm, appr. |
1345 |
1665 |
2375 |
2645 |
3145 |
| |
| Temperature Tests |
| Temperature Range |
TS -40/..., CS -40/... |
°C |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
| TS -70/..., CS -70/... |
°C |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
Temp. Change Rate Cooling |
TS -40/..., CS -40/... |
K/min |
10,0 |
10,0 |
10,0 |
10,0 |
10,0 |
| acc. IEC 60068-3-5 |
TS -70/..., CS -70/... |
K/min |
11,0 |
10,0 |
10,0 |
10,0 |
10,0 |
Temp. Change Rate Heating |
TS -40/..., CS -40/... |
K/min |
12,0 |
10,0 |
10,0 |
10,0 |
10,0 |
| acc. IEC 60068-3-5 |
TS -70/..., CS -70/... |
K/min |
12,0 |
10,0 |
10,0 |
10,0 |
10,0 |
max. Thermal Load at +20°C |
TS -40/..., CS -40/... |
W |
5000 |
5000 |
7000 |
8000 |
8000 |
| TS -70/..., CS -70/... |
W |
4000 |
5000 |
5500 |
8000 |
8000 |
| Temperature Fluctuation |
K |
≤± 0,3 temporally |
| |
| Climatic Tests |
| Temperature Range |
CS -40/..., CS -70/... |
°C |
+10 to +95 |
| Humidity Range |
CS -40/..., CS -70/... |
% RH |
10 to 98 |
| Dew Point Range I |
CS -40/..., CS -70/... |
°C |
+7 to +94 |
| Dew Point Range II |
CS -40/..., CS -70/... |
°C |
-10 to +7 |
| Humidity Fluctuation I |
CS -40/..., CS -70/... |
% RH |
≤± 1,5 |
| Humidity Fluctuation II |
CS -40/..., CS -70/... |
% RH |
≤± 3 |
| Temperature Fluctuation |
CS -40/..., CS -70/... |
K |
≤± 0,3 |
| Nominal Voltage |
400 V +6% -10%, 3/N, 50 Hz |
| Nominal Power |
TS -40/... |
kW, appr. |
13,4 |
13,4 |
17,5 |
23,0 |
32,0 |
| CS -40/... |
kW, appr. |
13,4 |
13,4 |
18,6 |
24,1 |
33,0 |
| TS -70/... |
kW, appr. |
16,6 |
16,6 |
20,3 |
26,0 |
37,0 |
| CS -70/... |
kW, appr. |
16,6 |
16,6 |
20,3 |
26,0 |
35,8 |
| Condenser |
|
water-cooled |
| Weight |
TS -40/..., CS -40/... |
kg, appr. |
600 |
700 |
800 |
1000 |
1150 |
| TS -40/..., CS -40/... |
kg, appr. |
650 |
750 |
900 |
1100 |
1300 |
| Noise level |
|
dB(A) |
< 58 |
< 58 |
< 68 |
< 68 |
< 73 |
|
Type |
15 K/min |
|
|
TS -40/..., CS -40/... TS -70/..., CS -70/... |
-40/280-15 -70/280-15 |
-40/500-15 -70/500-15 |
-40/810-15 -70/810-15 |
-40/1250-5 -70/1250-15 |
|
Test Space |
liters |
280 |
500 |
810 |
1250 |
|
Test Space Dimensions |
|
height |
mm, appr. |
720 |
820 |
870 |
870 |
| |
width |
mm, appr. |
650 |
850 |
1000 |
1000 |
| |
depth |
mm, appr. |
615 |
730 |
900 |
1400 |
|
Overall Dimensions |
|
height |
mm, appr. |
2080 |
2170 |
2230 |
2230 |
| |
width |
mm, appr. |
920 |
1120 |
1270 |
1270 |
| |
depth |
mm, appr. |
2165 |
2375 |
2645 |
3145 |
| |
|
Temperature Tests |
|
Temperature Range |
TS -40/..., CS -40/... |
°C |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
| TS -70/..., CS -70/... |
°C |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
Temp. Change Rate Cooling |
TS -40/..., CS -40/... |
K/min |
15,0 |
15,0 |
15,0 |
15,0 |
|
acc. IEC 60068-3-5 |
TS -70/..., CS -70/... |
K/min |
15,0 |
15,0 |
15,0 |
15,0 |
Temp. Change Rate Heating |
TS -40/..., CS -40/... |
K/min |
15,0 |
15,0 |
15,0 |
15,0 |
|
acc. IEC 60068-3-5 |
TS -70/..., CS -70/... |
K/min |
15,0 |
15,0 |
15,0 |
15,0 |
max. Thermal Load at +20°C |
TS -40/..., CS -40/... |
W |
5000 |
8000 |
8000 |
8000 |
| TS -70/..., CS -70/... |
W |
5000 |
8000 |
8000 |
8000 |
|
Temperature Fluctuation |
K |
≤± 0,3 temporally |
| |
|
Climatic Tests |
|
Temperature Range |
CS -40/..., CS -70/... |
°C |
+10 to +95 |
|
Humidity Range |
CS -40/..., CS -70/... |
% RH |
10 to 98 |
|
Dew Point Range I |
CS -40/..., CS -70/... |
°C |
+7 to +94 |
|
Dew Point Range II |
CS -40/..., CS -70/... |
°C |
-10 to +7 |
|
Humidity Fluctuation I |
CS -40/..., CS -70/... |
% RH |
≤± 1,5 |
|
Humidity Fluctuation II |
CS -40/..., CS -70/... |
% RH |
≤± 3 |
|
Temperature Fluctuation |
CS -40/..., CS -70/... |
K |
≤± 0,3 |
|
Nominal Voltage |
400 V +6% -10%, 3/N, 50 Hz |
|
Nominal Power |
TS -40/... |
kW, appr. |
17,6 |
24,0 |
32,0 |
42,5 |
| CS -40/... |
kW, appr. |
18,7 |
24,0 |
33,0 |
43,6 |
| TS -70/... |
kW, appr. |
21,2 |
27,4 |
37,1 |
46,8 |
| CS -70/... |
kW, appr. |
21,2 |
27,4 |
35,8 |
46,8 |
|
Condenser |
|
water-cooled |
| Weight |
TS -40/..., CS -40/... |
kg, appr. |
800 |
900 |
1100 |
1350 |
| TS -40/..., CS -40/... |
kg, appr. |
900 |
1000 |
1200 |
1500 |
| Noise level |
|
dB(A) |
< 68 |
< 68 |
< 73 |
< 75 |
|
Temperature Change Rate acc. IEC 60068-3-5: |
| heating |
= |
Δ th / Δ Th |
| cooling |
= |
Δ tk / Δ Tk |

Temperature Change Rate acc. IEC 60068-3-5
Δ Th = time of heating
Δ Tk = time of cooling
Δ th = temperature difference, heating
Δ tk = temperature difference, cooling |
All figures are average values which have been obtained at a temperature of +25° C, without test specimens, without thermal load and without options.
We reserve the right to make alterations due to technical development.
Other chamber sizes and options on request.
|
|