Climatic Test Cabinets, Series C

In addition to the advantages already mentioned for our temperature test cabinets, CTS climatic test cabinets also offer you the possibility of including humidity as a stress factor in your simulation tests. The humidity is measured by a capacitive humidity sensor, which is distinguished by its high accuracy, long-term stability and low maintenance requirements. Generally as a medium sized company CTS places great value on the detailed quality of all system components, whereby only the best supplier products, such as compressors and solenoid valves are used. This results in advantages for you in the form of long-term, malfunction-free operation to ensure that you do not lose valuable testing time.

Climatic Test Cabinets, Series C -70/350

Standard version of the product line "C":

multicolor touch panel / 32 Bit Controller
service-friendly capacitive humidity measurement system
single-hand operated door handle, lockable
entry port ø 50 mm
shelf, stainless steel
error display in plain text
potential free contact for malfunction signal
RS 232 interface


Your benefits:

service-friendly construction
minimum noise level
high temperature change rate
simple user-friendly operation and programming
low power-consumption datas
optimized parameters for highest testing precision
complies with current CE and EMC regulation


Test space capacity in liters:

100 / 200 / 350 / 600 / 1000 / 1500


Temperature range:

+10 °C / +180 °C
 -20 °C / +180 °C
 -40 °C / +180 °C
 -70 °C / +180 °C


Humidity range:

10 - 95 % RH


Design:

Control: microprocessor control and monitoring system
Test space: stainless steel grade 1.4301
Refrigerants: chloride free, hermetically sealed
Humidity system: capacitive measuring


Options:

add. entry ports ø 50 mm, 80 mm und 125 mm
add. shelves
panoramic window, multiple glazed, sized 570 x 710 mm; for units ≥ 200 ltr.
hand-hole in the door
add. Pt 100 for temperature measuring on test specimen alternative reversible to controller function
air dryer system
mobile unit design
temperature protection for test-specimen
water cooled compressor
CID software for programming and documentation
variable air speed in the test space
RS 232 interface changeable to USB
ETHERNET interface RJ 45

 

  Type C -40/100
C -65/100
C -40/200
C -70/200
C -40/350
C -70/350
C -40/600
C -70/600
C -40/1000
C -70/1000
C -40/1500
C -70/1500
Test Space liters 100 200 350 600 1000 1500
Test Space Dimensions height mm, appr. 500 750 750 850 900 900
width mm, appr. 500 650 650 850 1000 1000
depth mm, appr. 400 400 720 830 1100 1600
Overall Dimensions height mm, appr. 1630 1800 1800 1900 1950 1950
width mm, appr. 770 920 920 1120 1270 1270
depth mm, appr. 860 1345 1665 1875 2245 2745
 
Temperature Tests
Temperature Range C -40/... °C -40/+180 -40/+180 -40/+180 -40/+180 -40/+180 -40/+180
C -70/... °C -65/+180 -70/+180 -70/+180 -70/+180 -70/+180 -70/+180
Temp. Change Rate Cooling
acc. IEC 60068-3-6
C -40/... K/min 5,0 4,0 4,0 3,5 3,0 2,5
C -70/... K/min 2,0 4,0 3,5 3,0 2,5 2,0
Temp. Change Rate Heating
acc. IEC 60068-3-6
C -40/... K/min 3,0 4,0 3,5 3,5 3,0 3,5
C -70/... K/min 3,0 4,0 3,5 3,5 2,5 3,5
max. Thermal Load
at +20°C
C -40/... W 1400 3500 3500 4000 4000 4000
C -70/... W 700 3000 3000 4000 4000 4000
Temperature Fluctuation K ≤± 0,3 temporally
 
Climatic Tests
Temperature Range °C +10 to +95
Humidity Range % RH 10 to 98
Dew Point Range I °C -7 to +94
Dew Point Range II °C -7 to +7 -10 to +7  
Humidity Fluctuation I % RH ≤± 1,5
Humidity Fluctuation II % RH ≤± 3
Temperature Fluctuation K ≤± 0,3
 
Nominal Voltage 230 V
+6% -10%
1/N
50 Hz
400 V +6% -10%, 3/N, 50 Hz
Nominal Power C -40/... kW, appr. 4,1 7,1 7,1 8,2 8,5 9,2
C -70/... kW, appr. 4,1 7,1 7,1 8,7 8,9 10,8
Condenser   air-cooled
Weight C -40/... kg, appr. 350 450 500 550 800 950
C -70/... kg, appr. 380 500 550 600 850 1050
Noise level

dB(A)

55 < 58 < 58 < 58 < 58 < 58

All figures are average values which have been obtained at a temperature of +25° C, without test specimens, without thermal load and without options.
We reserve the right to make alterations due to technical development.

Other chamber sizes and options on request.